Introbotics
Introbotics
image
image
image
image
 

CI REPORT WRITER™
image

 

The CI Report Writer™ is designed to produce a customize report of all the numerical controlled impedance test data and to generate histograms. The Writer also provides the capability to generate an “Out of Center” report with programmable conditions against any data set. The CI Report Writer™ provides a way to customize a query of the CI1000™ or ACCU-Prober™ database to extract only the test results you need regardless of when or for whom the test data was taken. The Writer also allows you to sort the data results by board serial number (for pass/fail reports) and by test point (for statistical analysis). You can then select only the data you want to appear on the test report (mean impedance, prop delay, effective Er, Equivalent Trace Bandwidth, etc.) including statistical data calculations.

 

The CI Report Writer Capabilities
image

Filter by Operator  
Filter by Customer  
Filter by Date  
Order by ICN (Tool Number/Part Number)  
Order by Job Number (Order Number/Traveler Number)  
Order by Date Code  
Order by Date  
Search by ICN, Job Number, Date Code, or Date  
Filter by Final or In-process Test  
Filter by Pass or Fail (# of Failures per board)  
Filter by Single-ended or Differential  
Report on all traces or only one trace  
Present a report with data group by Serial Number or by Trace test point  
Report on the following parameters:  
  Pass/Fail  
  Minimum Impedance  
  Mean Impedance  
  Mean Impedance (Differential)  
  Maximum Impedance  
  Propagation Delay  
  Propagation Delay (Differential)  
  Propagation Velocity  
  Effective Er  
  Transition Duration  
  Transition Duration (Differential)  
  Interconnect Bandwidth  
  Interconnect Bandwidth (Differential)  

 

Statistical Data
image

The following statistical data can be calculated:
 

Average  
Standard Deviation
3 Sigma
5 Sigma
Maximum Value
Minimum Value
Range
Cp
Cpk


Histograms can be generated for any data set which is reported. Out of Center Report can be generated with programmable setting

Finally, the Writer allows you to either printout the report or to export the report in a number of different data formats including (MSWord®, MSExcel®, Adobe Acrobat, etc.)

 

CI Report Writer User Screen
(click image to enlarge)

 

 

"Out of Center" Report
(click image to enlarge)

 

 

Go Back

INTROBOTICS CORPORATION
4208 Balloon Park Road NE  Albuquerque, NM 87109
Tel: (505) 345-7785 Fax: (505) 345-7790 Email: info@introbotics.com

Home | About Us | Accu-Prober | CI1000 | HFT-1500 | Our Services | Contact Us
Controlled Impedence | Library | Introbotics News | Awards | Careers

 
image
image
image