Minimum Board Size |
|
|
 |
5 1/4" x 1/2" (133mm x
12.7mm) |
 |
Maximum Panel Size |
|
|
 |
36" x 28.5" (914mm x
724mm) |
 |
System Rise/Fall Times |
|
|
 |
35 psec rise time, 50 psec fall time |
 |
Measurement Accuracy |
|
|
 |
Minimum Trace Length: 0.5" |
 |
Impedance Accuracy: <0.1 ohms |
 |
Repeatability: 0.05 ohms (standard deviation) |
 |
Propagation Delay Accuracy: TDR Jitter: 1 psec ±5PPM of position |
 |
TDR Horizontal Accuracy: 1 psec ±1% of the interval |
 |
TDR Instrumentation
Interface |
|
|
 |
Tektronix DSA8200 with 80E04 TDR Sampling Head
Module |
 |
Probe Connections |
|
|
 |
Two (2), 3.5mm connectors (SMA
compatible)
|
 |
Probe Rate |
|
|
 |
Single-ended: >30 tests per minute |
 |
Differential: >28 tests per minute |
 |
System Probing Area |
|
|
 |
X-axis: 33" (838mm) |
 |
Y-axis: 27.5" (699mm) |
 |
Temperature |
|
|
 |
Operating: +10°C to +40°C |
 |
Storage: -22°C to +60°C |
 |
Relative Humidity |
|
|
 |
Operating: 20% to 80% at or below 40°C |
 |
Storage: 5% to 90% at or below 60°C |
 |
Power Requirements |
|
|
 |
Line voltage Ranges: 90-132 VAC, 180-250 VAC |
 |
Line Frequency: 48-440 Hz |