Introbotics
Introbotics
image
image
image
image
 

The CI1000
Robotic Controlled Impedance Tester
image
Specifications

 CI1000 System Specificationsimage

Minimum Board Size
  5 1/4" x 1/2" (133mm x 12.7mm)
Maximum Panel Size
  36" x 28.5" (914mm x 724mm)
System Rise/Fall Times
  35 psec rise time, 50 psec fall time
Measurement Accuracy
 
Minimum Trace Length: 0.5"
Impedance Accuracy: <0.1 ohms
Repeatability: 0.05 ohms (standard deviation)
Propagation Delay Accuracy: TDR Jitter: 1 psec ±5PPM of position
TDR Horizontal Accuracy: 1 psec ±1% of the interval
TDR Instrumentation Interface
 
Tektronix DSA8200 with 80E04 TDR Sampling Head Module
Probe Connections
  Two (2), 3.5mm connectors (SMA compatible)
Probe Rate
  Single-ended:  >30 tests per minute
Differential:  >28 tests per minute
System Probing Area
  X-axis:  33" (838mm)
Y-axis:  27.5" (699mm)
Temperature
  Operating: +10°C to +40°C
Storage: -22°C to +60°C
Relative Humidity
  Operating: 20% to 80% at or below 40°C
Storage: 5% to 90% at or below 60°C
Power Requirements
  Line voltage Ranges: 90-132 VAC, 180-250 VAC
Line Frequency: 48-440 Hz

 

 

Installation Requirements:image

Air

  Air quality:Clean and dry
Consumption: Minimal (Gallons/min)
Pressure: 90(PSI)
Electric
  Voltage: 110-208 VAC, 3 phase
Recommended External Circuit Breaker: 20 Amps
Frequency: 60 Hz

Operating Environment

  Temperature: 5 C to 40C (41 to 104F)
Relative Humidity: 5 to 90% noncondensing
Pollution degree: 2 (per IEC 1131-2/EN 61131-2)
Floor space
  Machine Size:66" x 70"
System weight: Approx. 1300 Lbs.

 

 

CI1000 Industry Test Standards Compliantimage

TM-650 2.5.5.7  (IPC-2141)
Intel (Rambus) PCB Test Methodology
IEC 326-3 (IEC 61188) Controlled Impedance

 

 

CI1000™ Links
image

The terms CI1000™, ACCU-Prober™ and WaveForm Viewer™ are trademarked and may not be used except with the permission of Introbotics. The CI1000™ probe and CI1000™ system are patented and the WaveForm Viewer™ software and Report Writer software are copyrighted and may not be used except with the permission of Introbotics.

 

INTROBOTICS CORPORATION
4208 Balloon Park Road NE  Albuquerque, NM 87109
Tel: (505) 345-7785 Fax: (505) 345-7790 Email: info@introbotics.com

Home | About Us | Accu-Prober | CI1000 | HFT-1500 | Our Services | Contact Us
Controlled Impedence | Library | Introbotics News | Awards | Careers

 
image
image
image